Difference between revisions of "ATUEM4H1S09"

From Technical Support Wiki
Jump to: navigation, search
(Created page with "ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of ''Blue Series 2''. right|thumb|''Blue Series 2'' evaporator (9k) == Remote Control == F...")
 
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of ''[[Blue Series 2]]''. [[File:Blue2-9-24k-evap.png|right|thumb|''Blue Series 2'' evaporator (9k)]]
+
ATUEM4H1S09 is the 19 SEER 9,000 Btu indoor unit of ''[[Titanium Series]]''. [[File:115V-IDU-1.png|right|thumb|''Titanium Series'' evaporator (9k)]]
 
== Remote Control ==
 
== Remote Control ==
 
[[File:Blue-series-2-remote.png|left|thumb|200px|Remote Control]]
 
[[File:Blue-series-2-remote.png|left|thumb|200px|Remote Control]]
Line 64: Line 64:
 
|}
 
|}
 
== Wiring Diagram ==
 
== Wiring Diagram ==
[[File:Blue2-9-12k-IDU-WDF.png|none|thumb|500px|ABSEM4H4S09 Wiring Diagram]]
+
[[File:Titanium-9-12k-IDU-WD.png|none|thumb|500px|ATUEM4H1S09 Wiring Diagram]]
  
 
== PCB Printed Diagram ==  
 
== PCB Printed Diagram ==  
[[File:Blue2-9-12k-IDU-PCB.png|right|thumb|500px|ABSEM4H4S09 PCB Printed Diagram]]
+
[[File:Blue2-9-12k-IDU-PCB.png|right|thumb|500px|ATUEM4H1S09 PCB Printed Diagram]]
 
{| class="wikitable"
 
{| class="wikitable"
 
! Number
 
! Number
Line 106: Line 106:
  
 
== Exploded View and Parts List ==  
 
== Exploded View and Parts List ==  
[[File:Blue2-9-12k-IDU-EV.png|left|thumb|500px|ABSEM4H4S09 Exploded View]]
+
[[File:Titanium-9k-IDU-EV.png|left|thumb|500px|ATUEM4H1S09 Exploded View]]
 
{| class="wikitable"
 
{| class="wikitable"
 
! Number
 
! Number
Line 124: Line 124:
 
|-
 
|-
 
| 5  
 
| 5  
| Center Staff
+
| Level Vane
 
|-
 
|-
 
| 6
 
| 6
| Center Staff
+
| Cross Flow Fan Blade
 
|-
 
|-
 
| 7  
 
| 7  
| Center Staff
+
| Bearing
 
|-
 
|-
 
| 8  
 
| 8  
| Step Motor
+
| Baffle
 
|-
 
|-
 
| 9  
 
| 9  
| Motor Guard
+
| Refrigeration System
 
|-
 
|-
 
| 10
 
| 10
| Level Vane
+
| Motor Guard
 
|-
 
|-
 
| 11
 
| 11
| Cross-Flow Fan Blade
+
| Fan Motor
 
|-
 
|-
 
| 12
 
| 12
| Bearing
+
| Motor Cover
 
|-
 
|-
 
| 13
 
| 13
| Baffle
+
| Remote Controller
 
|-
 
|-
 
| 14
 
| 14
| Refrigeration System
+
| Electric Box Cover
 
|-
 
|-
 
| 15
 
| 15
| Motor Guard
+
| Temperature Sensor
 
|-
 
|-
 
| 16  
 
| 16  
| Fan Motor
+
| Temperature Sensor 
 
|-
 
|-
 
| 17
 
| 17
| Motor Cover
+
| Over Clamp
 
|-
 
|-
 
| 18
 
| 18
| Remote Controller
+
| Wire Terminal Board
 
|-
 
|-
 
| 19
 
| 19
Line 169: Line 169:
 
|-
 
|-
 
| 20
 
| 20
| Temperature Sensor
+
| Electric Joint Box Plate
 
|-
 
|-
 
| 21  
 
| 21  
| Temperature Sensor
+
| Indoor Main Control Board Component
 
|-
 
|-
 
| 22  
 
| 22  
| Over Clamp
+
| Electric Box
 
|-
 
|-
 
| 23
 
| 23
| Wire Terminal Board
+
| Electric Joint Box Plate
 
|-
 
|-
 
| 24
 
| 24
| Electric Box Cover
+
| Water Pipe Parts
 
|-
 
|-
 
| 25
 
| 25
| Electric Joint Box Plate 
+
| Axis Sheath
 
|-
 
|-
 
| 26
 
| 26
| Indoor Main Control Board Component 
+
| Step Motor
 
|-
 
|-
 
| 27
 
| 27
| Electric Box
+
| Shell
 
|-
 
|-
 
| 28  
 
| 28  
| Electric Joint Box Plate
+
| Ornamental Part
 
|-
 
|-
 
| 29
 
| 29
| Water Pipe Parts
+
| Ornamental Part
 
|-
 
|-
 
| 30
 
| 30
| Axis Sheath
+
| Display Component
 
|-
 
|-
 
| 31  
 
| 31  
| Step Motor
+
| Ornamental Part
 
|-
 
|-
 
| 32
 
| 32
| Shell
+
| Panel
 
|-
 
|-
 
| 33  
 
| 33  
| Display Component
+
| Display Film
|-
 
| 34
 
| Ornamental Part
 
|-
 
| 35
 
| Panel
 
|-
 
| Unnumbered
 
| Filter Net
 
 
|}
 
|}

Latest revision as of 15:08, 10 November 2017

ATUEM4H1S09 is the 19 SEER 9,000 Btu indoor unit of Titanium Series.

Titanium Series evaporator (9k)

Remote Control

Remote Control
# Name Description
1 ON/OFF Press to start or stop operation.
2 MODE Press to select operation mode (Auto/Cool/Dry/Fan/Heat).
3 FAN Used to select the fan speed in sequence: auto, high, medium, or low.
4 ROOM TEMPERATURE SETTING Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time.
5 ROOM TEMPERATURE SETTING Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time.
6 SMART Adjust smart settings.
7 SWING Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction.
8 SLEEP Used to set or cancel Sleep Mode operation.
9 IFEEL Used to set IFEEL operation.
10 CLOCK Used to set the current time.
11 TIMER ON Used to turn the timer function on.
12 TIMER OFF Used to turn the timer function off.
13 SUPER Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.)
14 DIMMER Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer.

Wiring Diagram

ATUEM4H1S09 Wiring Diagram

PCB Printed Diagram

ATUEM4H1S09 PCB Printed Diagram
Number Description
1 PG Motor Interface
2 Room temperature sensor
3 Pipe temperature sensor
4 Switch buton
5 Feedback from PG Motor
6 Up & down swing
7 Left & right swing
8 Wiring control or Wifi interface
9 Display interface
10 Protective tube



Exploded View and Parts List

ATUEM4H1S09 Exploded View
Number Part Name
1 Installation Plate Assy
2 Baffle
3 Base Holder Part
4 Vertical Level Vane
5 Level Vane
6 Cross Flow Fan Blade
7 Bearing
8 Baffle
9 Refrigeration System
10 Motor Guard
11 Fan Motor
12 Motor Cover
13 Remote Controller
14 Electric Box Cover
15 Temperature Sensor
16 Temperature Sensor
17 Over Clamp
18 Wire Terminal Board
19 Electric Box Cover
20 Electric Joint Box Plate
21 Indoor Main Control Board Component
22 Electric Box
23 Electric Joint Box Plate
24 Water Pipe Parts
25 Axis Sheath
26 Step Motor
27 Shell
28 Ornamental Part
29 Ornamental Part
30 Display Component
31 Ornamental Part
32 Panel
33 Display Film