Difference between revisions of "ATUEM4H1S09"
From Technical Support Wiki
(Created page with "ABSEM4H4S09 is the 22 SEER 9,000 Btu indoor unit of ''Blue Series 2''. right|thumb|''Blue Series 2'' evaporator (9k) == Remote Control == F...") |
|||
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | ATUEM4H1S09 is the 19 SEER 9,000 Btu indoor unit of ''[[Titanium Series]]''. [[File:115V-IDU-1.png|right|thumb|''Titanium Series'' evaporator (9k)]] | |
== Remote Control == | == Remote Control == | ||
[[File:Blue-series-2-remote.png|left|thumb|200px|Remote Control]] | [[File:Blue-series-2-remote.png|left|thumb|200px|Remote Control]] | ||
Line 64: | Line 64: | ||
|} | |} | ||
== Wiring Diagram == | == Wiring Diagram == | ||
− | [[File: | + | [[File:Titanium-9-12k-IDU-WD.png|none|thumb|500px|ATUEM4H1S09 Wiring Diagram]] |
== PCB Printed Diagram == | == PCB Printed Diagram == | ||
− | [[File:Blue2-9-12k-IDU-PCB.png|right|thumb|500px| | + | [[File:Blue2-9-12k-IDU-PCB.png|right|thumb|500px|ATUEM4H1S09 PCB Printed Diagram]] |
{| class="wikitable" | {| class="wikitable" | ||
! Number | ! Number | ||
Line 106: | Line 106: | ||
== Exploded View and Parts List == | == Exploded View and Parts List == | ||
− | [[File: | + | [[File:Titanium-9k-IDU-EV.png|left|thumb|500px|ATUEM4H1S09 Exploded View]] |
{| class="wikitable" | {| class="wikitable" | ||
! Number | ! Number | ||
Line 124: | Line 124: | ||
|- | |- | ||
| 5 | | 5 | ||
− | | | + | | Level Vane |
|- | |- | ||
| 6 | | 6 | ||
− | | | + | | Cross Flow Fan Blade |
|- | |- | ||
| 7 | | 7 | ||
− | | | + | | Bearing |
|- | |- | ||
| 8 | | 8 | ||
− | | | + | | Baffle |
|- | |- | ||
| 9 | | 9 | ||
− | | | + | | Refrigeration System |
|- | |- | ||
| 10 | | 10 | ||
− | | | + | | Motor Guard |
|- | |- | ||
| 11 | | 11 | ||
− | | | + | | Fan Motor |
|- | |- | ||
| 12 | | 12 | ||
− | | | + | | Motor Cover |
|- | |- | ||
| 13 | | 13 | ||
− | | | + | | Remote Controller |
|- | |- | ||
| 14 | | 14 | ||
− | | | + | | Electric Box Cover |
|- | |- | ||
| 15 | | 15 | ||
− | | | + | | Temperature Sensor |
|- | |- | ||
| 16 | | 16 | ||
− | | | + | | Temperature Sensor |
|- | |- | ||
| 17 | | 17 | ||
− | | | + | | Over Clamp |
|- | |- | ||
| 18 | | 18 | ||
− | | | + | | Wire Terminal Board |
|- | |- | ||
| 19 | | 19 | ||
Line 169: | Line 169: | ||
|- | |- | ||
| 20 | | 20 | ||
− | | | + | | Electric Joint Box Plate |
|- | |- | ||
| 21 | | 21 | ||
− | | | + | | Indoor Main Control Board Component |
|- | |- | ||
| 22 | | 22 | ||
− | | | + | | Electric Box |
|- | |- | ||
| 23 | | 23 | ||
− | | | + | | Electric Joint Box Plate |
|- | |- | ||
| 24 | | 24 | ||
− | | | + | | Water Pipe Parts |
|- | |- | ||
| 25 | | 25 | ||
− | | | + | | Axis Sheath |
|- | |- | ||
| 26 | | 26 | ||
− | | | + | | Step Motor |
|- | |- | ||
| 27 | | 27 | ||
− | | | + | | Shell |
|- | |- | ||
| 28 | | 28 | ||
− | | | + | | Ornamental Part |
|- | |- | ||
| 29 | | 29 | ||
− | | | + | | Ornamental Part |
|- | |- | ||
| 30 | | 30 | ||
− | | | + | | Display Component |
|- | |- | ||
| 31 | | 31 | ||
− | | | + | | Ornamental Part |
|- | |- | ||
| 32 | | 32 | ||
− | | | + | | Panel |
|- | |- | ||
| 33 | | 33 | ||
− | | Display | + | | Display Film |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|} | |} |
Latest revision as of 15:08, 10 November 2017
ATUEM4H1S09 is the 19 SEER 9,000 Btu indoor unit of Titanium Series.
Remote Control
# | Name | Description |
1 | ON/OFF | Press to start or stop operation. |
2 | MODE | Press to select operation mode (Auto/Cool/Dry/Fan/Heat). |
3 | FAN | Used to select the fan speed in sequence: auto, high, medium, or low. |
4 | ROOM TEMPERATURE SETTING | Press to raise the temperature setting. Can also be used to adjust the timer and adjust the current time. |
5 | ROOM TEMPERATURE SETTING | Press to lower the temperature setting. Can also be used to adjust the timer and adjust the current time. |
6 | SMART | Adjust smart settings. |
7 | SWING | Used to stop or start vertical adjustment louver swinging and set the desired up/down airflow direction. |
8 | SLEEP | Used to set or cancel Sleep Mode operation. |
9 | IFEEL | Used to set IFEEL operation. |
10 | CLOCK | Used to set the current time. |
11 | TIMER ON | Used to turn the timer function on. |
12 | TIMER OFF | Used to turn the timer function off. |
13 | SUPER | Used to start/stop the super cool/heat function. (Super cooling operates at high fan speed with a default 64 F temperature setting. Super heating operates at high fan speed with a default 89 F temperature setting.) |
14 | DIMMER | Pressing this button will dim the display on the indoor unit. Pressing any button will reverse the dimmer. |
Wiring Diagram
PCB Printed Diagram
Number | Description |
---|---|
1 | PG Motor Interface |
2 | Room temperature sensor |
3 | Pipe temperature sensor |
4 | Switch buton |
5 | Feedback from PG Motor |
6 | Up & down swing |
7 | Left & right swing |
8 | Wiring control or Wifi interface |
9 | Display interface |
10 | Protective tube |
Exploded View and Parts List
Number | Part Name |
---|---|
1 | Installation Plate Assy |
2 | Baffle |
3 | Base Holder Part |
4 | Vertical Level Vane |
5 | Level Vane |
6 | Cross Flow Fan Blade |
7 | Bearing |
8 | Baffle |
9 | Refrigeration System |
10 | Motor Guard |
11 | Fan Motor |
12 | Motor Cover |
13 | Remote Controller |
14 | Electric Box Cover |
15 | Temperature Sensor |
16 | Temperature Sensor |
17 | Over Clamp |
18 | Wire Terminal Board |
19 | Electric Box Cover |
20 | Electric Joint Box Plate |
21 | Indoor Main Control Board Component |
22 | Electric Box |
23 | Electric Joint Box Plate |
24 | Water Pipe Parts |
25 | Axis Sheath |
26 | Step Motor |
27 | Shell |
28 | Ornamental Part |
29 | Ornamental Part |
30 | Display Component |
31 | Ornamental Part |
32 | Panel |
33 | Display Film |