|
|
(4 intermediate revisions by the same user not shown) |
Line 1: |
Line 1: |
| AMTCM4H4R18 is the 22 SEER, 18,000 BTU dual zone multi split unit. | | AMTCM4H4R18 is the 22 SEER, 18,000 BTU dual zone multi split unit. |
− | [[File:Multi-cond.png|thumb|right|Multi Split Condenser]] | + | [[File:New_Multi_Split_18K-Med.png|thumb|right|Multi Split Condenser (18K)]] |
| == Wiring Diagram== | | == Wiring Diagram== |
| [[File:New-Multi-18K-ODU-WD.png|none|thumb|500px|AMTCM4H4R18 Wiring Diagram]] | | [[File:New-Multi-18K-ODU-WD.png|none|thumb|500px|AMTCM4H4R18 Wiring Diagram]] |
Line 132: |
Line 132: |
| ! Liquid Side | | ! Liquid Side |
| ! Gas Side | | ! Gas Side |
− | ! Evaporators | + | ! Wall Mount Evaporators (A16) |
| + | ! Wall Mount Evaporators (AMT) |
| |- | | |- |
| | 1/4" | | | 1/4" |
| | 3/8" | | | 3/8" |
− | | A16EM4H4R09 <br />A16EM4H4R12 | + | | A16EW4H4R09 <br />A16EW4H4R12 |
| + | | AMTEM4H4R09 <br />AMTEM4H4R12 |
| |- | | |- |
| | 1/4" | | | 1/4" |
| | 1/2" | | | 1/2" |
− | | A16EM4H4R18 | + | | A16EW4H4R18 |
| + | | AMTEM4H4R18 |
| |} | | |} |
− | == Malfunction Indicator ==
| |
− | Note: When several malfunctions occur at the same time, they will be displayed in circulation and every malfunction is displayed for 5 seconds.
| |
− | {| class="wikitable"
| |
− | | NO.
| |
− | | Malfunction description
| |
− | | LED1
| |
− | | LED2
| |
− | | LED3
| |
− | | LED4
| |
− | |-
| |
− | | 0
| |
− | | Normal stop
| |
− | | off
| |
− | | off
| |
− | | off
| |
− | | off
| |
− | |-
| |
− | | 1
| |
− | | Compressor run
| |
− | | on
| |
− | | off
| |
− | | off
| |
− | | off
| |
− | |-
| |
− | | 2
| |
− | | Compressor overload protection
| |
− | | blinking
| |
− | | off
| |
− | | off
| |
− | | off
| |
− | |-
| |
− | | 3
| |
− | | Discharge protection
| |
− | | off
| |
− | | on
| |
− | | off
| |
− | | off
| |
− | |-
| |
− | | 4
| |
− | | Outdoor unit overload protection
| |
− | | on
| |
− | | on
| |
− | | off
| |
− | | off
| |
− | |-
| |
− | | 5
| |
− | | High pressure protection
| |
− | | blinking
| |
− | | on
| |
− | | off
| |
− | | off
| |
− | |-
| |
− | | 6
| |
− | | Over current protection
| |
− | | off
| |
− | | blinking
| |
− | | off
| |
− | | off
| |
− | |-
| |
− | | 7
| |
− | | [[IMP Protection Malfunction(Multi ODU)|IMP protection]]
| |
− | | on
| |
− | | blinking
| |
− | | off
| |
− | | off
| |
− | |-
| |
− | | 8
| |
− | | IMP overheating protection
| |
− | | blinking
| |
− | | blinking
| |
− | | off
| |
− | | off
| |
− | |-
| |
− | | 9
| |
− | | [[PFC Protection Malfunction (Multi ODU)|PFC protection (including PFC overheating protection)]]
| |
− | | off
| |
− | | off
| |
− | | on
| |
− | | off
| |
− | |-
| |
− | | 10
| |
− | | Phase current protection
| |
− | | on
| |
− | | off
| |
− | | on
| |
− | | off
| |
− | |-
| |
− | | 11
| |
− | | Over voltage protection
| |
− | | blinking
| |
− | | off
| |
− | | on
| |
− | | off
| |
− | |-
| |
− | | 12
| |
− | | Insufficient voltage protection
| |
− | | off
| |
− | | on
| |
− | | on
| |
− | | off
| |
− | |-
| |
− | | 13
| |
− | | Start failure
| |
− | | on
| |
− | | on
| |
− | | on
| |
− | | off
| |
− | |-
| |
− | | 14
| |
− | | [[Compressor Desynchronizing Malfunction (Multi ODU)|Compressor desynchronizing]]
| |
− | | blinking
| |
− | | on
| |
− | | on
| |
− | | off
| |
− | |-
| |
− | | 15
| |
− | | Compressor phase-lacking protection
| |
− | | off
| |
− | | blinking
| |
− | | on
| |
− | | off
| |
− | |-
| |
− | | 16
| |
− | | Compressor phase current detection malfunction
| |
− | | on
| |
− | | blinking
| |
− | | on
| |
− | | off
| |
− | |-
| |
− | | 17
| |
− | | Memory chip mistake
| |
− | | blinking
| |
− | | blinking
| |
− | | on
| |
− | | off
| |
− | |-
| |
− | | 18
| |
− | | DC power supply short-circuit
| |
− | | off
| |
− | | off
| |
− | | blinking
| |
− | | off
| |
− | |-
| |
− | | 19
| |
− | | Defrosting
| |
− | | on
| |
− | | off
| |
− | | blinking
| |
− | | off
| |
− | |-
| |
− | | 20
| |
− | | Oil return
| |
− | | blinking
| |
− | | off
| |
− | | blinking
| |
− | | off
| |
− | |-
| |
− | | 21
| |
− | | Complete unit frequency restriction protection
| |
− | | off
| |
− | | on
| |
− | | blinking
| |
− | | off
| |
− | |-
| |
− | | 22
| |
− | | Complete unit frequency dropping protection
| |
− | | on
| |
− | | on
| |
− | | blinking
| |
− | | off
| |
− | |-
| |
− | | 23
| |
− | | Unit A frequency restriction or frequency dropping protection
| |
− | | blinking
| |
− | | on
| |
− | | blinking
| |
− | | off
| |
− | |-
| |
− | | 24
| |
− | | Unit B frequency restriction or frequency dropping protection
| |
− | | off
| |
− | | blinking
| |
− | | blinking
| |
− | | off
| |
− | |-
| |
− | | 25
| |
− | | Unit C frequency restriction or frequency dropping protection
| |
− | | on
| |
− | | blinking
| |
− | | blinking
| |
− | | off
| |
− | |-
| |
− | | 26
| |
− | | Unit D frequency restriction or frequency dropping protection
| |
− | | blinking
| |
− | | blinking
| |
− | | blinking
| |
− | | off
| |
− | |-
| |
− | | 27
| |
− | | Outdoor ambient temperature sensor protection
| |
− | | off
| |
− | | off
| |
− | | off
| |
− | | on
| |
− | |-
| |
− | | 28
| |
− | | Outdoor tube temperature sensor protection
| |
− | | on
| |
− | | off
| |
− | | off
| |
− | | on
| |
− | |-
| |
− | | 29
| |
− | | Discharge temperature sensor protection
| |
− | | blinking
| |
− | | off
| |
− | | off
| |
− | | on
| |
− | |-
| |
− | | 30
| |
− | | IPM thermal resistance malfunction
| |
− | | off
| |
− | | on
| |
− | | off
| |
− | | on
| |
− | |-
| |
− | | 31
| |
− | | Unit A liquid pipe temperature sensor malfunction
| |
− | | on
| |
− | | on
| |
− | | off
| |
− | | on
| |
− | |-
| |
− | | 32
| |
− | | Unit A gas pipe temperature sensor malfunction
| |
− | | blinking
| |
− | | on
| |
− | | off
| |
− | | on
| |
− | |-
| |
− | | 33
| |
− | | Unit B liquid pipe temperature sensor malfunction
| |
− | | off
| |
− | | blinking
| |
− | | off
| |
− | | on
| |
− | |-
| |
− | | 34
| |
− | | Unit B gas pipe temperature sensor malfunction
| |
− | | on
| |
− | | blinking
| |
− | | off
| |
− | | on
| |
− | |-
| |
− | | 35
| |
− | | Unit C liquid pipe temperature sensor malfunction
| |
− | | blinking
| |
− | | blinking
| |
− | | off
| |
− | | on
| |
− | |-
| |
− | | 36
| |
− | | Unit C gas pipe temperature sensor malfunction
| |
− | | off
| |
− | | off
| |
− | | on
| |
− | | on
| |
− | |-
| |
− | | 37
| |
− | | Unit D liquid pipe temperature sensor malfunction
| |
− | | on
| |
− | | off
| |
− | | on
| |
− | | on
| |
− | |-
| |
− | | 38
| |
− | | Unit D gas pipe temperature sensor malfunction
| |
− | | blinking
| |
− | | off
| |
− | | on
| |
− | | on
| |
− | |-
| |
− | | 39
| |
− | | Unit A mode conflict
| |
− | | off
| |
− | | on
| |
− | | on
| |
− | | on
| |
− | |-
| |
− | | 40
| |
− | | Unit B mode conflict
| |
− | | on
| |
− | | on
| |
− | | on
| |
− | | on
| |
− | |-
| |
− | | 41
| |
− | | Unit C mode conflict
| |
− | | blinking
| |
− | | on
| |
− | | on
| |
− | | on
| |
− | |-
| |
− | | 42
| |
− | | Unit D mode conflict
| |
− | | off
| |
− | | blinking
| |
− | | on
| |
− | | on
| |
− | |-
| |
− | | 43
| |
− | | Communication failure with Unit A
| |
− | | on
| |
− | | blinking
| |
− | | on
| |
− | | on
| |
− | |-
| |
− | | 44
| |
− | | Communication failure with Unit B
| |
− | | blinking
| |
− | | blinking
| |
− | | on
| |
− | | on
| |
− | |-
| |
− | | 45
| |
− | | Communication failure with Unit C
| |
− | | off
| |
− | | off
| |
− | | blinking
| |
− | | on
| |
− | |-
| |
− | | 46
| |
− | | Communication failure with Unit D
| |
− | | on
| |
− | | off
| |
− | | blinking
| |
− | | on
| |
− | |-
| |
− | | 47
| |
− | | Unit A freeze protection
| |
− | | blinking
| |
− | | off
| |
− | | blinking
| |
− | | on
| |
− | |-
| |
− | | 48
| |
− | | Unit B freeze protection
| |
− | | off
| |
− | | on
| |
− | | blinking
| |
− | | on
| |
− | |-
| |
− | | 49
| |
− | | Unit C freeze protection
| |
− | | on
| |
− | | on
| |
− | | blinking
| |
− | | on
| |
− | |-
| |
− | | 50
| |
− | | Unit D freeze protection
| |
− | | blinking
| |
− | | on
| |
− | | blinking
| |
− | | on
| |
− | |-
| |
− | | 51
| |
− | | Unit A overheating prevention protection
| |
− | | off
| |
− | | blinking
| |
− | | blinking
| |
− | | on
| |
− | |-
| |
− | | 52
| |
− | | Unit B overheating prevention protection
| |
− | | on
| |
− | | blinking
| |
− | | blinking
| |
− | | on
| |
− | |-
| |
− | | 53
| |
− | | Unit C overheating prevention protection
| |
− | | blinking
| |
− | | blinking
| |
− | | blinking
| |
− | | on
| |
− | |-
| |
− | | 54
| |
− | | Unit D overheating prevention protection
| |
− | | off
| |
− | | off
| |
− | | off
| |
− | | blinking
| |
− | |-
| |
− | | 55
| |
− | | Unit A communication wire misconnection or expansion valve malfunction
| |
− | | on
| |
− | | off
| |
− | | off
| |
− | | blinking
| |
− | |-
| |
− | | 56
| |
− | | Unit B communication wire misconnection or expansion valve malfunction
| |
− | | blinking
| |
− | | off
| |
− | | off
| |
− | | blinking
| |
− | |-
| |
− | | 57
| |
− | | Unit C communication wire misconnection or expansion valve malfunction
| |
− | | off
| |
− | | on
| |
− | | off
| |
− | | blinking
| |
− | |-
| |
− | | 58
| |
− | | Unit D communication wire misconnection or expansion valve malfunction
| |
− | | on
| |
− | | on
| |
− | | off
| |
− | | blinking
| |
− | |}
| |
− | == Common Troubleshooting ==
| |
− | The following outline solutions for malfunctions that are either not indicated by the LEDs or cover more than one malfunction number in the above table.
| |
− | * [[Capacity Charging Malfunction (Multi ODU)|Capacity Charging Malfunction]]
| |
− | * [[Anti-High Temperature and Overload Malfunction (Multi ODU)|Anti-High Temperature and Overload Malfunction]]
| |
− | * [[Temperature Sensor Malfunction (Multi ODU)| Temperature Sensor Malfunction]]
| |
− | * [[Start Failure Malfunction (Multi ODU)|Start Failure Malfunction]]
| |
− | * [[Communication Malfunction (Multi ODU)|Communication Malfunction]]
| |
− | * [[Compressor Overload/Discharge Protection Malfunction (Multi ODU)|Compressor Overload/Discharge Protection Malfunction]]
| |
| == Accessories == | | == Accessories == |
| *[[Wall Bracket (QBR-19.5)]] | | *[[Wall Bracket (QBR-19.5)]] |
| *[[Universal Remote (QTH-4000)]] | | *[[Universal Remote (QTH-4000)]] |