Difference between revisions of "APV Rooftop Series Specs"

From Technical Support Wiki
Jump to: navigation, search
 
(4 intermediate revisions by the same user not shown)
Line 129: Line 129:
 
| 860
 
| 860
 
| 1100
 
| 1100
 +
|-
 +
! scope="col" colspan="2" rowspan="2"  | External Static Pressure
 +
| Pa
 +
| 125
 +
| 125
 +
| 125
 +
|-
 +
| InWg
 +
| 0.50
 +
| 0.50
 +
| 0.50
 +
|-
 +
! scope="col" colspan="2" rowspan="2"  | External Static Pressure Range
 +
| Pa
 +
| 0-250
 +
| 0-250
 +
| 0-250
 +
|-
 +
| InWg
 +
| 0-1
 +
| 0-1
 +
| 0-1
 +
|-
 +
! scope="col" colspan="2" | Sound Pressure Level (H)
 +
| dB(A)
 +
| 65
 +
| 68
 +
| 68
 +
|-
 +
! scope="col" colspan="2" | Sound Power Level (H)
 +
| dB(A)
 +
| 75
 +
| 78
 +
| 78
 +
|-
 +
! scope="col" colspan="2" | Recommended Power Cable (Core)
 +
| N
 +
| 3
 +
| 3
 +
| 3
 +
|-
 +
! scope="col" colspan="2" | Fuse Current
 +
| A
 +
| 45
 +
| 45
 +
| 45
 +
|-
 +
! scope="col" colspan="2" | Circuit Breaker
 +
| A
 +
| 45
 +
| 45
 +
| 45
 +
|-
 +
! scope="col" colspan="2" | Cooling Power Input
 +
| kW
 +
| 3.11
 +
| 4.27
 +
| 5.70
 +
|-
 +
! scope="col" colspan="2" | Heating Power Input
 +
| kW
 +
| 3.10
 +
| 4.10
 +
| 5.25
 +
|-
 +
! scope="col" colspan="2" | Max. Over Current Protection
 +
| A
 +
| 45
 +
| 45
 +
| 45
 +
|-
 +
! scope="col" colspan="2" | Min Current (MCA)
 +
| A
 +
| 39.1
 +
| 39.1
 +
| 39.1
 +
|-
 +
! scope="col" colspan="2" rowspan="2" | Drainage Connection Size(Outer Diameter×Wall Thickness)
 +
| mm
 +
| 19.05
 +
| 19.05
 +
| 19.05
 +
|-
 +
| inch
 +
| 3/4
 +
| 3/4
 +
| 3/4
 +
|-
 +
! scope="col" colspan="2" | Permissible Excessive Operating Pressure for the Discharge Side
 +
| MPa
 +
| 3.8
 +
| 3.8
 +
| 3.8
 +
|-
 +
! scope="col" colspan="2" | Permissible Excessive Operating Pressure for the Suction Side
 +
| MPa
 +
| 1.7
 +
| 1.7
 +
| 1.7
 +
|-
 +
! scope="col" colspan="2" | Maximum Allowable Pressure
 +
| MPa
 +
| 4.2
 +
| 4.5
 +
| 4.5
 +
|-
 +
! scope="col" colspan="2" rowspan="2" | Cooling Operation Ambient Temp Range
 +
| ℃
 +
| -5~52
 +
| -5~52
 +
| -5~52
 +
|-
 +
| ℉
 +
| 23~125
 +
| 23~125
 +
| 23~125
 +
|-
 +
! scope="col" colspan="2" rowspan="2" | Heating Operation Ambient Temp Range
 +
| ℃
 +
| -30~24
 +
| -30~24
 +
| -30~24
 +
|-
 +
| ℉
 +
| -22~75.2
 +
| -22~75.2
 +
| -22~75.2
 +
|-
 +
! scope="col" colspan="2" | System Operation Control
 +
| -
 +
| Wired
 +
| Wired
 +
| Wired
 +
|-
 +
! scope="col" colspan="2" | Defrosting Method
 +
| -
 +
| Automatic Defrosting
 +
| Automatic Defrosting
 +
| Automatic Defrosting
 +
|-
 +
! scope="col" colspan="2" | Isolation
 +
| -
 +
| I Class
 +
| I Class
 +
| I Class
 +
|-
 +
! scope="col" colspan="2" | Moisture Protection
 +
| -
 +
| IPX4
 +
| IPX4
 +
| IPX4
 +
|-
 +
! scope="col" colspan="2" | Climate Type
 +
| -
 +
| T3
 +
| T3
 +
| T3
 +
|-
 +
! scope="col" colspan="2" | Refrigerant
 +
| -
 +
| R410A
 +
| R410A
 +
| R410A
 +
|-
 +
! scope="col" colspan="2" rowspan="2" | Refrigerant Charge
 +
| kg
 +
| 5
 +
| 6.7
 +
| 6.7
 +
|-
 +
| oz
 +
| 176.4
 +
| 236.4
 +
| 236.4
 +
|-
 +
! scope="col" colspan="2" | Cooling Throttling Method
 +
| -
 +
| Electronic Expansion Valve
 +
| Electronic Expansion Valve
 +
| Electronic Expansion Valve
 +
|-
 +
! scope="col" colspan="2" | Heating Throttling Method
 +
| -
 +
| Electronic Expansion Valve
 +
| Electronic Expansion Valve
 +
| Electronic Expansion Valve
 
|-
 
|-

Latest revision as of 20:30, 11 January 2024

Parameter Unit Value
Model APIV4H4R03 APIV4H4R04 APIV4H4R05
Power Supply Rated Voltage V 208/230 208/230 208/230
Rated Frequency Hz 60 60 60
Phases - 1 1 1
Cooling Cooling Capacity kW 10.05 13.77 16.70
BTU/h 34300 47000 57000
ton 3 4 5
Heating Heating Capacity kW 10.55 13.77 16.70
BTU/h 36000 47000 57000
ton 3 4 5
EER W/W 3.23 3.22 2.93
(BTU/h)/W 11.00 11.00 10.00
COP W/W 3.24 3.36 3.18
(BTU/h)/W 11.60 11.46 10.86
SEER - 18.00 18.00 17.00
HSPF - 8.80 8.50 8.30
Air Flow Volume (H) m3/h 1900 2300 2700
CFM 1120 1350 1600
Air Flow Volume (M) m3/h 1360 1550 2000
CFM 800 900 1200
Air Flow Volume (L) m3/h 1190 1450 1850
CFM 700 860 1100
External Static Pressure Pa 125 125 125
InWg 0.50 0.50 0.50
External Static Pressure Range Pa 0-250 0-250 0-250
InWg 0-1 0-1 0-1
Sound Pressure Level (H) dB(A) 65 68 68
Sound Power Level (H) dB(A) 75 78 78
Recommended Power Cable (Core) N 3 3 3
Fuse Current A 45 45 45
Circuit Breaker A 45 45 45
Cooling Power Input kW 3.11 4.27 5.70
Heating Power Input kW 3.10 4.10 5.25
Max. Over Current Protection A 45 45 45
Min Current (MCA) A 39.1 39.1 39.1
Drainage Connection Size(Outer Diameter×Wall Thickness) mm 19.05 19.05 19.05
inch 3/4 3/4 3/4
Permissible Excessive Operating Pressure for the Discharge Side MPa 3.8 3.8 3.8
Permissible Excessive Operating Pressure for the Suction Side MPa 1.7 1.7 1.7
Maximum Allowable Pressure MPa 4.2 4.5 4.5
Cooling Operation Ambient Temp Range -5~52 -5~52 -5~52
23~125 23~125 23~125
Heating Operation Ambient Temp Range -30~24 -30~24 -30~24
-22~75.2 -22~75.2 -22~75.2
System Operation Control - Wired Wired Wired
Defrosting Method - Automatic Defrosting Automatic Defrosting Automatic Defrosting
Isolation - I Class I Class I Class
Moisture Protection - IPX4 IPX4 IPX4
Climate Type - T3 T3 T3
Refrigerant - R410A R410A R410A
Refrigerant Charge kg 5 6.7 6.7
oz 176.4 236.4 236.4
Cooling Throttling Method - Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Heating Throttling Method - Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve