Difference between revisions of "Bronze Series"
From Technical Support Wiki
| (17 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
| − | This is the support page for the Air-Con ''Bronze Series'' mini split line. | + | '''''The Bronze Series was discontinued in late 2014. All information preserved here is for legacy support.''''' |
| − | + | ---- | |
| − | + | This is the support page for the Air-Con ''Bronze Series'' mini split line. | |
| − | == Outdoor | + | {{Infobox |
| + | | | ||
| + | | bodyclass = infobox | ||
| + | | name = Bronze Series | ||
| + | | title = Bronze Series | ||
| + | | subheader = Single Zone Mini Split Line | ||
| + | | image = [[File: Bronze-featured.png|center|300px]] | ||
| + | |||
| + | | header1 = | ||
| + | | label1 = Voltage | ||
| + | | data1 = 115V-220V | ||
| + | | header2 = | ||
| + | | label2 = SEER Rating | ||
| + | | data2 = 13 | ||
| + | | header3 = | ||
| + | | label3 = Capacities | ||
| + | | data3 = 9,000 - 24,000 BTU | ||
| + | | header4 = | ||
| + | | label4 = Heat Pump? | ||
| + | | data4 = Yes | ||
| + | | header5 = | ||
| + | | label5 = Model Sold From | ||
| + | | data5 = May 2010 - May 2014 | ||
| + | }} | ||
| + | == Indoor Units == | ||
| + | * [[A13EM4H4G09]] | ||
| + | * [[A13EM4H4G12]] | ||
| + | * [[A13EM4H4G18]] | ||
| + | * [[A13EM4H4G24]] | ||
| + | == Outdoor Units == | ||
* [[A13CH4H4G09]] | * [[A13CH4H4G09]] | ||
* [[A13CH4H4G12]] | * [[A13CH4H4G12]] | ||
* [[A13CH4H4G18]] | * [[A13CH4H4G18]] | ||
* [[A13CH4H4G24]] | * [[A13CH4H4G24]] | ||
| − | |||
| − | |||
| − | |||
| − | |||
| − | |||
== Error Codes == | == Error Codes == | ||
{| class="wikitable" | {| class="wikitable" | ||
! Code | ! Code | ||
! Error Name | ! Error Name | ||
| − | ! | + | ! Troubleshooting |
|- | |- | ||
| DF | | DF | ||
| Defrost | | Defrost | ||
| Currently in defrost mode. Will return to normal operations when defrost is finished. | | Currently in defrost mode. Will return to normal operations when defrost is finished. | ||
| + | |- | ||
| + | | FF | ||
| + | | Outdoor Low Temperature Indication | ||
| + | | The current temperature outside is too low for proper unit functionality. | ||
| + | |- | ||
| + | | E1 | ||
| + | | Outdoor Temp Sensor Fault | ||
| + | | | ||
| + | * Check whether the resistance of the sensor is normal. If it is abnormal the sensor should be replaced. | ||
| + | * Check whether there is a short circuit or open circuit in the wire of the sensor, and whether the plug is connected correctly. | ||
| + | * After checking for the above conditions and finding nothing, it check the electric control board. | ||
|- | |- | ||
| E2 | | E2 | ||
| Line 26: | Line 61: | ||
| | | | ||
* Check whether the resistance of the sensor is normal. If it is abnormal the sensor should be replaced. | * Check whether the resistance of the sensor is normal. If it is abnormal the sensor should be replaced. | ||
| − | * Check whether there is a short circuit or open circuit in the wire of the sensor, and | + | * Check whether there is a short circuit or open circuit in the wire of the sensor, and whether the plug is connected correctly. |
* After checking for the above conditions and finding nothing, it check the electric control board. | * After checking for the above conditions and finding nothing, it check the electric control board. | ||
|- | |- | ||
| Line 77: | Line 112: | ||
* Check whether indoor pipe temperature sensor is normal, and replace the sensor if it is abnormal. | * Check whether indoor pipe temperature sensor is normal, and replace the sensor if it is abnormal. | ||
* Check whether the system pressure is normal, if abnormal, you should check whether there is leakage and fill the refrigerant if need be. | * Check whether the system pressure is normal, if abnormal, you should check whether there is leakage and fill the refrigerant if need be. | ||
| − | |} | + | |} |
| + | |||
== Document Downloads == | == Document Downloads == | ||
*[[:File:13_SEER-User-Manual-F.pdf|User's Manual]] | *[[:File:13_SEER-User-Manual-F.pdf|User's Manual]] | ||
*[[:File:13_SEER-Service-Manual.pdf|Service Manual]] | *[[:File:13_SEER-Service-Manual.pdf|Service Manual]] | ||
== Warranty Information == | == Warranty Information == | ||
| − | Each ''Bronze Series'' unit has a warranty of 1 years for parts and 5 years for the compressor. If you need more information, please visit the Air-Con [ | + | Each ''Bronze Series'' unit has a warranty of 1 years for parts and 5 years for the compressor. If you need more information, please visit the Air-Con [[Warranty Policy]] page. |
Latest revision as of 16:08, 13 October 2020
The Bronze Series was discontinued in late 2014. All information preserved here is for legacy support.
This is the support page for the Air-Con Bronze Series mini split line.
| Single Zone Mini Split Line | |
| Voltage | 115V-220V |
|---|---|
| SEER Rating | 13 |
| Capacities | 9,000 - 24,000 BTU |
| Heat Pump? | Yes |
| Model Sold From | May 2010 - May 2014 |
Indoor Units
Outdoor Units
Error Codes
| Code | Error Name | Troubleshooting |
|---|---|---|
| DF | Defrost | Currently in defrost mode. Will return to normal operations when defrost is finished. |
| FF | Outdoor Low Temperature Indication | The current temperature outside is too low for proper unit functionality. |
| E1 | Outdoor Temp Sensor Fault |
|
| E2 | Room Temp Sensor Fault |
|
| E3 | Coil Temp. Sensor Fault |
|
| E4 | Outdoor Unit Abnormal |
|
| E5 | No Feedback Signal of Indoor Fan |
|
| E6 | No Over Zero Signal |
|
| E7 | Outdoor Feedback Fault |
|
| E8 | Frost/Overheat Protection |
|
Document Downloads
Warranty Information
Each Bronze Series unit has a warranty of 1 years for parts and 5 years for the compressor. If you need more information, please visit the Air-Con Warranty Policy page.