Difference between revisions of "Silver Series"
From Technical Support Wiki
(Created page with "This is the support page for the Air-Con Silver Series mini split line. Here you will find information pertaining to common issues with the Silver Series units.") |
|||
Line 1: | Line 1: | ||
This is the support page for the Air-Con Silver Series mini split line. Here you will find information pertaining to common issues with the Silver Series units. | This is the support page for the Air-Con Silver Series mini split line. Here you will find information pertaining to common issues with the Silver Series units. | ||
+ | |||
+ | == Error Codes == | ||
+ | The error codes are displayed on the indoor unit's display board. Specifically, the display board's temperature indicator. | ||
+ | === Error E0 === | ||
+ | ''EEPROM parameter error'' | ||
+ | === Error E1 === | ||
+ | ''Indoor / outdoor units communication protection'' | ||
+ | === Error E2 === | ||
+ | ''Zero-crossing signal error'' | ||
+ | === Error E3 === | ||
+ | ''Indoor fan speed out of control" | ||
+ | === Error E5 === | ||
+ | ''Open or short circuit of outdoor temperature sensor'' | ||
+ | === Error E6 === | ||
+ | ''Open or short circuit of room or evaporator temperature sensor'' | ||
+ | === Error E7 === | ||
+ | ''Outdoor fan speed out of control'' | ||
+ | === Error P0 === | ||
+ | ''IGBT overstrong current protection'' | ||
+ | === Error P1 === | ||
+ | ''Over voltage or too low voltage protection'' | ||
+ | === Error P2 === | ||
+ | ''Temperature protection of compressor top'' | ||
+ | === Error P3 === | ||
+ | ''Inverter compressor drive error'' |
Revision as of 16:58, 6 November 2013
This is the support page for the Air-Con Silver Series mini split line. Here you will find information pertaining to common issues with the Silver Series units.
Error Codes
The error codes are displayed on the indoor unit's display board. Specifically, the display board's temperature indicator.
Error E0
EEPROM parameter error
Error E1
Indoor / outdoor units communication protection
Error E2
Zero-crossing signal error
Error E3
Indoor fan speed out of control"
Error E5
Open or short circuit of outdoor temperature sensor
Error E6
Open or short circuit of room or evaporator temperature sensor
Error E7
Outdoor fan speed out of control
Error P0
IGBT overstrong current protection
Error P1
Over voltage or too low voltage protection
Error P2
Temperature protection of compressor top
Error P3
Inverter compressor drive error