Difference between revisions of "Air-Con Multi Split"

From Technical Support Wiki
Jump to: navigation, search
(Replaced content with "This is the support page for the Air-Con multi split line. Here you will find information pertaining to common issues with the multi split units. == Indoor Units == * A...")
Line 9: Line 9:
 
* [[A16CM4H4R36]]
 
* [[A16CM4H4R36]]
 
* [[A16CM4H4R39]]
 
* [[A16CM4H4R39]]
−
== Malfunction Indicators ==
 
−
{| class="wikitable"
 
−
| NO.
 
−
| Malfunction description
 
−
| LED1
 
−
| LED2
 
−
| LED3
 
−
| LED4
 
−
|-
 
−
| 0
 
−
| Normal stop
 
−
| off
 
−
| off
 
−
| off
 
−
| off
 
−
|-
 
−
| 1
 
−
| Compressor run
 
−
| on
 
−
| off
 
−
| off
 
−
| off
 
−
|-
 
−
| 2
 
−
| Compressor overload protection
 
−
| blinking
 
−
| off
 
−
| off
 
−
| off
 
−
|-
 
−
| 3
 
−
| Discharge protection
 
−
| off
 
−
| on
 
−
| off
 
−
| off
 
−
|-
 
−
| 4
 
−
| Outdoor unit overload protection
 
−
| on
 
−
| on
 
−
| off
 
−
| off
 
−
|-
 
−
| 5
 
−
| High pressure protection
 
−
| blinking
 
−
| on
 
−
| off
 
−
| off
 
−
|-
 
−
| 6
 
−
| Over current protection
 
−
| off
 
−
| blinking
 
−
| off
 
−
| off
 
−
|-
 
−
| 7
 
−
| IMP protection
 
−
| on
 
−
| blinking
 
−
| off
 
−
| off
 
−
|-
 
−
| 8
 
−
| IMP overheating protection
 
−
| blinking
 
−
| blinking
 
−
| off
 
−
| off
 
−
|-
 
−
| 9
 
−
| PFC protection (including PFC overheating protection)
 
−
| off
 
−
| off
 
−
| on
 
−
| off
 
−
|-
 
−
| 10
 
−
| Phase current protection
 
−
| on
 
−
| off
 
−
| on
 
−
| off
 
−
|-
 
−
| 11
 
−
| Over voltage protection
 
−
| blinking
 
−
| off
 
−
| on
 
−
| off
 
−
|-
 
−
| 12
 
−
| Insufficient voltage protection
 
−
| off
 
−
| on
 
−
| on
 
−
| off
 
−
|-
 
−
| 13
 
−
| Start failure
 
−
| on
 
−
| on
 
−
| on
 
−
| off
 
−
|-
 
−
| 14
 
−
| Compressor desynchronizing
 
−
| blinking
 
−
| on
 
−
| on
 
−
| off
 
−
|-
 
−
| 15
 
−
| Compressor phase-lacking protection
 
−
| off
 
−
| blinking
 
−
| on
 
−
| off
 
−
|-
 
−
| 16
 
−
| Compressor phase current detection malfunction
 
−
| on
 
−
| blinking
 
−
| on
 
−
| off
 
−
|-
 
−
| 17
 
−
| Memory chip mistake
 
−
| blinking
 
−
| blinking
 
−
| on
 
−
| off
 
−
|-
 
−
| 18
 
−
| DC power supply short-circuit
 
−
| off
 
−
| off
 
−
| blinking
 
−
| off
 
−
|-
 
−
| 19
 
−
| Defrosting
 
−
| on
 
−
| off
 
−
| blinking
 
−
| off
 
−
|-
 
−
| 20
 
−
| Oil return
 
−
| blinking
 
−
| off
 
−
| blinking
 
−
| off
 
−
|-
 
−
| 21
 
−
| Complete unit frequency restriction protection
 
−
| off
 
−
| on
 
−
| blinking
 
−
| off
 
−
|-
 
−
| 22
 
−
| Complete unit frequency dropping protection
 
−
| on
 
−
| on
 
−
| blinking
 
−
| off
 
−
|-
 
−
| 23
 
−
| Unit A frequency restriction or frequency dropping protection
 
−
| blinking
 
−
| on
 
−
| blinking
 
−
| off
 
−
|-
 
−
| 24
 
−
| Unit B frequency restriction or frequency dropping protection
 
−
| off
 
−
| blinking
 
−
| blinking
 
−
| off
 
−
|-
 
−
| 25
 
−
| Unit C frequency restriction or frequency dropping protection
 
−
| on
 
−
| blinking
 
−
| blinking
 
−
| off
 
−
|-
 
−
| 26
 
−
| Unit D frequency restriction or frequency dropping protection
 
−
| blinking
 
−
| blinking
 
−
| blinking
 
−
| off
 
−
|-
 
−
| 27
 
−
| Outdoor ambient temperature sensor protection
 
−
| off
 
−
| off
 
−
| off
 
−
| on
 
−
|-
 
−
| 28
 
−
| Outdoor tube temperature sensor protection
 
−
| on
 
−
| off
 
−
| off
 
−
| on
 
−
|-
 
−
| 29
 
−
| Discharge temperature sensor protection
 
−
| blinking
 
−
| off
 
−
| off
 
−
| on
 
−
|-
 
−
| 30
 
−
| IPM thermal resistance malfunction
 
−
| off
 
−
| on
 
−
| off
 
−
| on
 
−
|-
 
−
| 31
 
−
| Unit A liquid pipe temperature sensor malfunction
 
−
| on
 
−
| on
 
−
| off
 
−
| on
 
−
|-
 
−
| 32
 
−
| Unit A gas pipe temperature sensor malfunction
 
−
| blinking
 
−
| on
 
−
| off
 
−
| on
 
−
|-
 
−
| 33
 
−
| Unit B liquid pipe temperature sensor malfunction
 
−
| off
 
−
| blinking
 
−
| off
 
−
| on
 
−
|-
 
−
| 34
 
−
| Unit B gas pipe temperature sensor malfunction
 
−
| on
 
−
| blinking
 
−
| off
 
−
| on
 
−
|-
 
−
| 35
 
−
| Unit C liquid pipe temperature sensor malfunction
 
−
| blinking
 
−
| blinking
 
−
| off
 
−
| on
 
−
|-
 
−
| 36
 
−
| Unit C gas pipe temperature sensor malfunction
 
−
| off
 
−
| off
 
−
| on
 
−
| on
 
−
|-
 
−
| 37
 
−
| Unit D liquid pipe temperature sensor malfunction
 
−
| on
 
−
| off
 
−
| on
 
−
| on
 
−
|-
 
−
| 38
 
−
| Unit D gas pipe temperature sensor malfunction
 
−
| blinking
 
−
| off
 
−
| on
 
−
| on
 
−
|-
 
−
| 39
 
−
| Unit A mode conflict
 
−
| off
 
−
| on
 
−
| on
 
−
| on
 
−
|-
 
−
| 40
 
−
| Unit B mode conflict
 
−
| on
 
−
| on
 
−
| on
 
−
| on
 
−
|-
 
−
| 41
 
−
| Unit C mode conflict
 
−
| blinking
 
−
| on
 
−
| on
 
−
| on
 
−
|-
 
−
| 42
 
−
| Unit D mode conflict
 
−
| off
 
−
| blinking
 
−
| on
 
−
| on
 
−
|-
 
−
| 43
 
−
| Communication failure with Unit A
 
−
| on
 
−
| blinking
 
−
| on
 
−
| on
 
−
|-
 
−
| 44
 
−
| Communication failure with Unit B
 
−
| blinking
 
−
| blinking
 
−
| on
 
−
| on
 
−
|-
 
−
| 45
 
−
| Communication failure with Unit C
 
−
| off
 
−
| off
 
−
| blinking
 
−
| on
 
−
|-
 
−
| 46
 
−
| Communication failure with Unit D
 
−
| on
 
−
| off
 
−
| blinking
 
−
| on
 
−
|-
 
−
| 47
 
−
| Unit A freeze protection
 
−
| blinking
 
−
| off
 
−
| blinking
 
−
| on
 
−
|-
 
−
| 48
 
−
| Unit B freeze protection
 
−
| off
 
−
| on
 
−
| blinking
 
−
| on
 
−
|-
 
−
| 49
 
−
| Unit C freeze protection
 
−
| on
 
−
| on
 
−
| blinking
 
−
| on
 
−
|-
 
−
| 50
 
−
| Unit D freeze protection
 
−
| blinking
 
−
| on
 
−
| blinking
 
−
| on
 
−
|-
 
−
| 51
 
−
| Unit A overheating prevention protection
 
−
| off
 
−
| blinking
 
−
| blinking
 
−
| on
 
−
|-
 
−
| 52
 
−
| Unit B overheating prevention protection
 
−
| on
 
−
| blinking
 
−
| blinking
 
−
| on
 
−
|-
 
−
| 53
 
−
| Unit C overheating prevention protection
 
−
| blinking
 
−
| blinking
 
−
| blinking
 
−
| on
 
−
|-
 
−
| 54
 
−
| Unit D overheating prevention protection
 
−
| off
 
−
| off
 
−
| off
 
−
| blinking
 
−
|-
 
−
| 55
 
−
| Unit A communication wire misconnection or expansion valve malfunction
 
−
| on
 
−
| off
 
−
| off
 
−
| blinking
 
−
|-
 
−
| 56
 
−
| Unit B communication wire misconnection or expansion valve malfunction
 
−
| blinking
 
−
| off
 
−
| off
 
−
| blinking
 
−
|-
 
−
| 57
 
−
| Unit C communication wire misconnection or expansion valve malfunction
 
−
| off
 
−
| on
 
−
| off
 
−
| blinking
 
−
|-
 
−
| 58
 
−
| Unit D communication wire misconnection or expansion valve malfunction
 
−
| on
 
−
| on
 
−
| off
 
−
| blinking
 
−
|}
 
 
== Warranty Information ==
 
== Warranty Information ==

Revision as of 19:14, 11 November 2013

This is the support page for the Air-Con multi split line. Here you will find information pertaining to common issues with the multi split units.

Indoor Units

Outdoor Units

Warranty Information