Difference between revisions of "Silver Series"

From Technical Support Wiki
Jump to: navigation, search
 
(19 intermediate revisions by the same user not shown)
Line 1: Line 1:
This is the support page for the Air-Con Silver Series mini split line. Here you will find information pertaining to common issues with the Silver Series units.
+
'''''The Silver Series was discontinued in early 2014. All information preserved here is for legacy support.'''''
 +
----
 +
This is the support page for the Air-Con ''Silver Series'' mini split line.
 +
{{Infobox
 +
|
 +
| bodyclass = infobox
 +
| name = Silver Series
 +
| title      = Silver Series
 +
| subheader  = Single Zone Mini Split Line
 +
| image = [[File:silver-featured.png|center|300px]]
 +
 +
| header1 =
 +
| label1 = Voltage
 +
| data1 = 220V
 +
| header2 =
 +
| label2 = SEER Rating
 +
| data2 = 17-22
 +
| header3 =
 +
| label3 = Capacities
 +
| data3 = 9,000 - 24,000 BTU
 +
| header4 =
 +
| label4 = Heat Pump?
 +
| data4 = No
 +
| header5 =
 +
| label5 = Model Sold From
 +
| data5 = June 2011 - April 2015
 +
}}
  
== Outdoor Models ==  
+
== Indoor Units ==
 +
* [[A17EM4C4M09]]
 +
* [[A18EM4C4M12]]
 +
* [[A17EM4C4M18]]
 +
* [[A22EM4C4M24]]
 +
 
 +
== Outdoor Units ==  
 
* [[A17CI4C4M09]]  
 
* [[A17CI4C4M09]]  
 
* [[A18CI4C4M12]]
 
* [[A18CI4C4M12]]
 
* [[A17CI4C4M18]]  
 
* [[A17CI4C4M18]]  
 
* [[A22CI4C4M24]]
 
* [[A22CI4C4M24]]
 
== Indoor Models ==
 
* A17EM4C4M09
 
* A18EM4C4M12
 
* A17EM4C4M18
 
* A22EM4C4M24
 
  
 
== Error Codes ==  
 
== Error Codes ==  
The error codes are displayed on the indoor unit's display board. Specifically, the display board's temperature indicator. All error codes are common among all of the Silver Series units.  
+
The error codes are displayed on the indoor unit's display board. Specifically, the display board's temperature indicator. All error codes are the same among all of the Silver Series units.  
=== Error E0 ===
+
* [[Error E0 (Silver Series)|Error E0]]
''EEPROM parameter error''
+
* [[Error E1 (Silver Series)|Error E1]]
=== Error E1 ===
+
* [[Error E2 (Silver Series)|Error E2]]
''Indoor / outdoor units communication protection''
+
* [[Error E3 (Silver Series)|Error E3]]
=== Error E2 ===
+
* [[Error E5 (Silver Series)|Error E5]]
''Zero-crossing signal error''
+
* [[Error E6 (Silver Series)|Error E6]]
=== Error E3 ===
+
* [[Error E7 (Silver Series)|Error E7]]
''Indoor fan speed out of control"
+
* [[Error P0 (Silver Series)|Error P0]]
=== Error E5 ===
+
* [[Error P1 (Silver Series)|Error P1]]
''Open or short circuit of outdoor temperature sensor''
+
* [[Error P2 (Silver Series)|Error P2]]
=== Error E6 ===
+
* [[Error P4 (Silver Series)|Error P4]]
''Open or short circuit of room or evaporator temperature sensor''
+
== Document Downloads ==
=== Error E7 ===
+
* [[:File:Silver_Series-Service-Manual.pdf|Service Manual]]
''Outdoor fan speed out of control''
+
* [[:File:Silver Series-User-Manual.pdf|User Manual]]
=== Error P0 ===
+
* [[:File:SILVER-REMOTE-MANUAL.PDF|Remote Control Manual]]
''IGBT overstrong current protection''
+
== Warranty Information ==  
=== Error P1 ===
+
Each ''Silver Series'' unit has a warranty of 2 years for parts and 5 years for the compressor. If you need more information, please visit the Air-Con [[Warranty Policy]] page.
''Over voltage or too low voltage protection''
 
=== Error P2 ===  
 
''Temperature protection of compressor top''
 
=== Error P3 ===  
 
''Inverter compressor drive error''
 

Latest revision as of 17:43, 16 November 2017

The Silver Series was discontinued in early 2014. All information preserved here is for legacy support.


This is the support page for the Air-Con Silver Series mini split line.

Silver Series
Single Zone Mini Split Line
Silver-featured.png
Voltage 220V
SEER Rating 17-22
Capacities 9,000 - 24,000 BTU
Heat Pump? No
Model Sold From June 2011 - April 2015

Indoor Units

Outdoor Units

Error Codes

The error codes are displayed on the indoor unit's display board. Specifically, the display board's temperature indicator. All error codes are the same among all of the Silver Series units.

Document Downloads

Warranty Information

Each Silver Series unit has a warranty of 2 years for parts and 5 years for the compressor. If you need more information, please visit the Air-Con Warranty Policy page.