ASPCI4H4S36

From Technical Support Wiki
Jump to: navigation, search

ASPCI4H4S36 is the 19 SEER 33,000 Btu outdoor unit of Eclipse Series (30K) mini split line.

Eclipse Series condenser (33k)

Wiring Diagram

ASPCI4H4S36 Wiring Diagram

PCB Printed Diagram

ASPCI4H4S36 PCB Diagram
Number Description
1 Terminal of Reactor
2 Terminal of Compressor
3 Terminal of DC Fan
4 Heat Sink Temperature Sensor
5 Pressure Protector
6 Compressor Discharge Temperature Sensor
7 Outdoor Ambient Temperature Sensor
8 Outdoor Pipe Temperature Sensor
9 Terminal of Compressor Overload Protector
10 Terminal of Electronic Expansion Valve
11 DRED Function
12 Terminal of AC Fan
13 Cool Valve Terminal
14 Heater Terminal
15 4-way Valve Terminal
16 Terminal of Communication Wire to Terminal Block
17 Terminal of Signal Wire to Terminal Block
18 Terminal of Neutral Wire to Terminal Block




Exploded View and Parts List

ASPCI4H4S36 Exploded View
Number Part Name
1 Panel Parts
2 Propeller Fan Blade
3 Fan Motor
4 Motor Supporter
5 Mounting Plate
6 Top Plate Part
7 Back Guard
8 Condenser Assembly
9 Base Holder Part
10 Valve Seat
11 PFC Inductance
12 4-way Valve Assembly
13 Compressor
14 Compressor Connect Wire
15 Electronic Expansion Valve Assy
16 2-way Valve
17 3-Way Valve
18 Right Side Board
19 Wiring Distribution Cover Assy
20 Electric Box
21 Connecting Board
22 Wire Terminal Board
23 Main Board Controller Component
24 Electric Box Cover
25 Ambient Temperature Sensor
26 Ambient Temperature Sensor
27 Ambient Temperature Sensor
28 4-way Valve Coil
29 4-way Valve

Piping Sizes

Liquid Side Gas Side
3/8" 5/8"

Accessories